Home » Products» Electronic Material» Ferrite Material
Products
Ferrite Material
NFC Sticker ferrite material on metal surface application
NFC Sticker ferrite material on metal surface application
  • Mobile phone with NFC Function

  • Contactless passive ID card,IC card

  • RFID reader with passive write tag function

  • RFID raw material Anti metal surface applications

  • Resistant raw materials for mount on metal surface

Description
  • NFC Sticker ferrite material on metal surface application

  • Increased improvement of mobile NFC system;

  • Production can flesible;

  • Increased magnetic field convergence by relative magnetic permeability

  • Type:Ferrite sheet

  • Effective carrier frequency:13.56MHZ and below

  • Operating temperature(.C):-30.C to +85.C

  • Permeability(@13.56MHZ) 獭:43.2395

  • Surface resistivity():>=108 R

  • Heat conductivity(W/m.k):1.0 W/m.k

  • Adhesive Tape:Customization Optional

  • Color:Black

  • Test device :HP4285A;

Permeability characteristic
  • The information and statements here are believed to be reliable but are not to be construed as a warranty or representation for which we assume legal responsibility.

  • Users should undertake sufficient verification and testing to determine the suitability for their own particular purpose of any information or products referred to herein.

Thickness and tolerance
Item codeDimenssion(mm)Cover thickness(mm)Adhesive thickness(mm)Total thickness(mm)Tolerance(mm)
IVF-N012-A1T-300x200Roll maximum 250mmx20m or sheet customilzedcustomilzed0.015/ 0.030.120.01
IVF-N023-A2T-300x200Roll maximum 250mmx20m or sheet customilzedcustomilzed0.015/ 0.030.230.01
IVF-N030-A2T-300x200Roll maximum 250mmx20m or sheet customilzedcustomilzed0.015/ 0.030.30.01
IVF-N045-A2T-300x200Roll maximum 250mmx20m or sheet customilzedcustomilzed0.015/ 0.030.450.01
IVF-N060-A2T-300x200Roll maximum 250mmx20m or sheet customilzedcustomilzed0.015/ 0.030.600.01
Reliability test
No.ITEMTEST CONDITIONTEST REQUIREMENTS
1High Temperature Resistance1. Temperature : +85 5
2. Time : 96 hrs
3. Measure after left for 60 min. at room
1. No visual damage
2. Permeability change within 15%
2Low Temperature Resistance1. Temperature : -40 5
2. Time : 96 hrs
3. Measure after left for 60 min. t room
1. No visual damage
2. Permeability change within 15%
3Humidity(Steady Condition)1. Humidity : 80 % RH
2. Temperature : +80 3
3. Time : 120 hrs
4. Measure after left for 60 min. at room
1. No visual damage
2. Permeability change within 15%

The information and statements here are believed to be reliable but are not to be construed as a warranty or representation for which we assume legal responsibility.

To Top